This page includes information on:
|
QC test |
Reported Value Equation |
Pass Test Equation |
|
MeasuredConc |
abs(ReportValue) <= CRQL |
|
|
MeasuredConc |
abs(ReportValue) <= CRQL |
|
|
MeasuredConc / DefinedConc * 100 |
(ReportValue >= LowerLimit) and (ReportValue <= UpperLimit) |
|
|
MeasuredConc / DefinedConc * 100 |
(ReportValue >= LowerLimit) and (ReportValue <= UpperLimit) |
|
|
MeasuredConc / DefinedConc * 100 |
(ReportValue >= LowerLimit) and (ReportValue <= UpperLimit) |
|
|
(MeasuredConc - MeasuredConc(PreviousSample)) / DefinedConc * 100 |
(ReportValue >= LowerLimit) and (ReportValue <= UpperLimit) |
|
|
|
Matrix Spike (MeasuredConc - MeasuredConc(PreviousSample)) / DefinedConc * 100 |
(ReportValue >= LowerLimit) and (ReportValue <= UpperLimit) |
|
Duplicate abs(MeasuredConc(MSPK) - MeasuredConc) / ((MeasuredConc(MSPK) + MeasuredConc) / 2) * 100 |
(ReportValue < PercentDiff) or (MeasuredConc < 5 * CRQL) |
|
|
abs(MeasuredConc(PreviousSample) - MeasuredConc) / abs((MeasuredConc(PreviousSample) + MeasuredConc) / 2) * 100 |
(ReportValue < PercentDiff) or (MeasuredConc < 5 * CRQL) |
|
|
MeasuredConc / DefinedConc * 100 |
(ReportValue >= LowerLimit) and (ReportValue <= UpperLimit) |
|
|
MeasuredConc |
abs(ReportValue) <= CRQL |
|
|
abs(MeasuredConc(PreviousSample) - MeasuredConc) / MeasuredConc(PreviousSample) * 100 |
(ReportValue < PercentDiff) or (MeasuredConc(PreviousSample) < 50*MDL) |
|
|
(MeasuredConc - MeasuredConc(PreviousSample)) / DefinedConc * 100 |
(ReportValue >= LowerLimit) and (ReportValue <= UpperLimit) |
|
|
MeasuredConc/DefinedConc * 100 |
(MeasuredConc >= min(DefinedConc*LowerLimit/100, DefinedConc-CRQL)) and (MeasuredConc <= max(DefinedConc*UpperLimit/100, DefinedConc+CRQL)) |
|
|
MeasuredConc/DefinedConc * 100 |
(MeasuredConc >= min(DefinedConc*LowerLimit/100, DefinedConc-CRQL)) and (MeasuredConc <= max(DefinedConc*UpperLimit/100, DefinedConc+CRQL)) |
|
|
Average(MeasuredConc) |
((ReportValue/DefinedConc * 100)>= LowerLimit) and ((ReportValue/DefinedConc * 100) <= UpperLimit) |
|
|
N/A |
1 > 0 |
|
QC test |
Reported Value Equation |
Pass Test Equation |
|
MeasuredConc / DefinedConc* 100 |
(ReportValue >= LowerLimit) and (ReportValue <= UpperLimit) |
|
|
Component - Inhalational |
InhalationalComponent |
ReportValue > = MeasuredConc |
|
Component - Oral |
OralComponent |
ReportValue > = MeasuredConc |
|
Component - Parenteral |
ParenteralComponent |
ReportValue > = MeasuredConc |
|
Control Threshold - Inhalational |
(InhalationalProduct / ((Volume / Weight) * Dilution * MMD)) * 0.3 |
ReportValue > = MeasuredConc / ((Volume / Weight) * Dilution) |
|
Control Threshold - Oral |
(OralProduct / ((Volume / Weight) * Dilution * MDD)) * 0.3 |
ReportValue > = MeasuredConc / ((Volume / Weight) * Dilution) |
|
Control Threshold - Parenteral |
(ParenteralProduct / ((Volume / Weight) * Dilution * MDD)) * 0.3 |
ReportValue > = MeasuredConc / ((Volume / Weight) * Dilution) |
|
(MeasuredConc - MeasuredConc(Previous Sample)) / DefinedConc * 100 |
(ReportValue >= LowerLimit) and (ReportValue <= UpperLimit) |
|
|
Product - Inhalational |
(InhalationalProduct / ((Volume / Weight) * Dilution * MMD)) |
ReportValue > = MeasuredConc / ((Volume / Weight) * Dilution) |
|
Product - Oral |
(OralProduct / ((Volume / Weight) * Dilution * MDD)) |
ReportValue > = MeasuredConc / ((Volume / Weight) * Dilution) |
|
Product - Parenteral |
(ParenteralProduct / ((Volume / Weight) * Dilution * MDD)) |
ReportValue > = MeasuredConc / ((Volume / Weight) * Dilution) |
** The "All Sample QC" Reported Value and Pass Test Equations are editable. All other Extended QC tests are not editable.